Specs

IBM FlashSystem Specs ... Compare the Models Before You Buy

Compare FlashSystem capacity and performance by model. Check the host connections and drive options before you pay for storage that does not fit.

Buying more TB will not fix slow storage if the bottleneck is elsewhere. Check the capacity and performance your applications need at their busiest time. Then compare the FlashSystem models below and ask the supplier to size the complete configuration.

Primary source: IBM Storage FlashSystem product comparison.

Expanding a FlashSystem 5200 or 7200? Check the model and FlashCore Module codes before ordering. A matching drive capacity does not make the feature code interchangeable.

IBM FlashSystem specifications at a glance

Current model figures follow IBM public comparison data where available. Prior-generation records emphasize refresh and migration decisions when current public figures are not the core buyer question.

ModelMachine TypeUse CaseRead BandwidthRead ResponseEffective Capacity
Array5127-A20Mixed workloads and smaller OLTP databases30 GB/sUnder 50 microseconds2.4 PBe
Array5075-A30Larger mixed and OLTP workloads55 GB/sUnder 50 microseconds7.2 PBe
Array5078-A40Consolidated mixed and critical OLTP workloads86 GB/sUnder 50 microseconds11.8 PBe
Array5202-C25Backup, sequential, and archival workloads23 GB/s1 to 2 milliseconds2.3 PBe
ArraySmaller mixed workloads and backup12 GB/sUnder 70 microseconds573 TBe
Array2072-2H2 / 2072-2H4Compare against FlashSystem 5015, 5035, 5045, C200, or current FlashSystem 5600 depending on workload
Array2072-2N2 / 2072-2N4 / 4662-2N2 / 4662-2N4 / 4680-2P2 / 4680-2P4Compare against FlashSystem 5000, 5045, C200, or current FlashSystem 5600 depending on workload
Array2078-4H4 classCompare against FlashSystem 5200, 5300, and current FlashSystem 5600
Array2072-3N2 / 2072-3N4Compare against FlashSystem 5045, C200, or current FlashSystem 5600 depending on workload
Array4680-3P2 / 4680-3P4Mixed workloads, virtualized environments, and budget-sensitive entry storageCompare against FlashSystem C200 or current FlashSystem 5600 based on workload shape
Array4662-6H2 (also shipped as 4662-UH6)70 microseconds
Array4662-7H2Compare against FlashSystem 5600
Array2072-3H2 (12-bay LFF) / 2072-3H4 (24-bay SFF)
ArrayLarger mixed and OLTP workloads55 GB/sUnder 50 microseconds7.2 PBe
Array2076-824 / 4664-824 / 2076-U7CCompare against FlashSystem 7300 and current FlashSystem 7600
Array4657-924Compare against FlashSystem 7600
ArrayConsolidated mixed and critical OLTP workloads86 GB/sUnder 50 microseconds11.8 PBe
Array9846-AG8 / 9848-AG8Compare against FlashSystem 9500 and current FlashSystem 9600
ArrayRack solution based on FlashSystem 9200 9846 / 9848 AG8 building blocksCompare against current FlashSystem 9600 or a multi-array 7600/9600 architecture
Array4666-AH8Large mixed workloads, critical OLTP, high capacity, and high bandwidthCompare against FlashSystem 9600
Array9848 / 9846 family (see 9110 and 9150 for specific models)
Array2076 family
Array9848-AF7 / 9846-AF7
Array9848-AC1 control enclosure / 9848-AE1 storage enclosureCompare migration paths into V9000, 9200, 9500, or current 9600
Array9848-AF8 / 9846-AF8
Array9846 / 9848 AC2 and AE2 familyCompare against FlashSystem 9200, 9500, or current 9600
Array9840-AE1 / 9843-AE1
Array9840-AE3 / 9843-AE3 / 9843-UF3 familyCompare against FlashSystem 7200, 9200, or current 5600/7600/9600 depending on workload
Array9836 / 9838 familyCompare migration paths into Storage Virtualize based FlashSystem models
Array9835 / 9837 familyCompare migration paths into current FlashSystem 7600 or 9600 based on workload and resilience design
Array9830-AE1
Array9830-AS1
Array2071-10A family
Array2072-12C family
Array2078-12F / 2078-24F family

IBM FlashSystem 5600

IBM FlashSystem 5600 machine type 5127-A20 is the compact current-generation choice for smaller mixed workloads, IBM Power attachment, and buyers who need 1U production storage without sizing into the 7600 tier.

IBM FlashSystem 7600

IBM FlashSystem 7600 machine type 5075-A30 is the current midrange choice for larger mixed workloads, more hosts, replication, virtualized consolidation, and buyers refreshing a 7300-class environment.

IBM FlashSystem 9600

IBM FlashSystem 9600 machine type 5078-A40 is the current flagship choice for critical OLTP, large mixed-workload consolidation, high bandwidth, high protected capacity, and 9500-class refresh decisions.

IBM FlashSystem C200

Capacity-optimized FlashSystem for backup, sequential, archive, media, and cost-sensitive high-capacity workloads where flash density and durability matter.

IBM FlashSystem 5000

Entry FlashSystem family category for smaller mixed workloads, backup, hybrid flash, and buyers comparing older 5010, 5015, 5030, 5035, and 5045 models.

IBM FlashSystem 5010

Entry 5000-family installed-base model for buyers checking 5010 LFF or SFF control enclosures, SAS drive media, support status, and replacement planning.

IBM FlashSystem 5015

Entry 5000-family installed-base model for buyers checking 5015 LFF or SFF control enclosures, 2072 and 4680 aliases, standard-drive media, support, and replacement planning.

IBM FlashSystem 5100

Installed-base compact NVMe FlashSystem model that often leads to 5200, 5300, or 5600 refresh comparisons and FCM2 compatibility checks.

IBM FlashSystem 5035

Entry 5000-family model for buyers checking 5035 LFF or SFF control enclosures, standard-drive media, support status, and 5045 or 5600 replacement planning.

IBM FlashSystem 5045

Entry 5000-family FlashSystem model for mixed workloads, virtualized environments, 4680-3P2 or 4680-3P4 searches, standard-drive configurations, and comparisons against 5015, 5035, C200, or 5600.

IBM FlashSystem 5200 Specs, Capacity and Upgrade Costs

Check the 4662-6H2 model and FlashCore Module options before adding capacity. Compare the cost of expanding your 5200 with moving to a newer FlashSystem.

IBM FlashSystem 5300

High-interest 1U NVMe FlashSystem still generating warehouse exposure, especially around 20 TB to 30 TB environments, datasheets, control enclosures, and refresh questions.

IBM FlashSystem 5030

SAS-based FlashSystem control enclosure, not part of the NVMe FlashCore Module line. 2072-3H2 is the 12-bay LFF control enclosure, 2072-3H4 is the 24-bay SFF control enclosure.

IBM FlashSystem 7000

Mid-range FlashSystem family category for consolidated virtualized estates, larger IBM i workloads, and buyers comparing the 7200, 7300, and current 7600.

IBM FlashSystem 7200 Specs, Support and Replacement Options

Check your FlashSystem 7200 model and FCM2 drives before spending on expansion. Compare what you can keep with the cost of a 7300 or 7600 replacement.

IBM FlashSystem 7300

High-interest midrange FlashSystem model for buyers comparing 7300-class replacements, Hitachi VSP One Block, Dell PowerStore, Pure Storage, and the current 7600 tier.

IBM FlashSystem 9000

Flagship FlashSystem family category for critical OLTP and large consolidation, covering the 9100, 9200, 9500, and current 9600 upgrade options.

IBM FlashSystem 9200

Installed-base high-end NVMe FlashSystem model for 9200 support, FCM2 media, V9000 or 9100 migration history, and 9500 or 9600 refresh planning.

IBM FlashSystem 9200R

Legacy rack-scale FlashSystem 9200R reference for buyers checking 9200R architecture, rack solution details, A9000R replacement context, and 9600 refresh planning.

IBM FlashSystem 9500

Previous flagship FlashSystem class for large mixed workloads, critical OLTP, and refresh conversations that usually point toward the current FlashSystem 9600 tier.

IBM FlashSystem 9100

The original NVMe FlashSystem family, IBM's first array built around FlashCore Module (FCM1) media, sold as the 9110 and 9150 SFF control enclosures.

IBM Storwize V7000 Migration Plan

Storwize V7000 remains a major query and migration signal. This profile frames the replacement decision toward FlashSystem 7600, 9600, or another architecture based on workload and risk.

IBM FlashSystem 9110

The entry model of IBM's original FlashSystem 9100 family, SFF NVMe control enclosure running first-generation FlashCore Modules, past standard support.

IBM FlashSystem V840

Legacy FlashSystem V840 reference for compatibility, support-history, V9000 replacement context, and migration planning from old 6U FlashSystem architecture.

IBM FlashSystem 9150

The performance tier of IBM's original FlashSystem 9100 family, SFF NVMe control enclosure running first-generation FlashCore Modules, past standard support.

IBM FlashSystem V9000

Legacy FlashSystem V9000 reference for support, migration, Storage Virtualize history, and refresh planning into later 9200, 9500, or 9600 models.

IBM FlashSystem 840

Relic 2U FlashSystem 840 reference for old compatibility, warranty, release-note, parts, and migration searches that should now point toward replacement planning.

IBM FlashSystem 900

Legacy FlashSystem 900 reference for support history, older flash enclosure compatibility, and migration planning toward newer FlashSystem storage.

IBM FlashSystem A9000

Legacy A9000 storage family reference for compatibility, microcode, XIV-lineage support research, and migration into newer FlashSystem designs.

IBM FlashSystem A9000R

Legacy rack-scale A9000R reference for 9835 and 9837 searches, support history, code-level research, and migration into modern FlashSystem storage.

IBM FlashSystem 810

Relic 1U FlashSystem 810 reference for old RamSan-era compatibility, warranty, security bulletin, parts, and replacement planning searches.

IBM FlashSystem 710

Relic 1U FlashSystem 710 reference for old RamSan-era compatibility, warranty, parts, security bulletin, and replacement planning searches.

IBM Storwize V3500

Relic Storwize V3500 reference for small installed-base environments, support-history checks, Storage Virtualize code context, and FlashSystem migration planning.

IBM Storwize V3700

Relic Storwize V3700 reference for support-history checks, small storage migration planning, and replacement with FlashSystem 5000, C200, or 5600.

IBM Storwize V5000

Legacy Storwize V5000 reference for support-history checks, Storage Virtualize migration planning, and replacement with FlashSystem 5000, 5100, 5200, or 5600.